Prepaid Dual-source Single-phase Keypad Smart Meter with Split-type Design

Prepaid Dual-source Single-phase Keypad Smart Meter with Split-type Design

Short Description

The CA168-MJ56 is a new generation single-phase multi-function meter with modular design. The meter is used to measure electrical energy accurately for commercial and residential customers. The meter has a wide range of functions and the possibility of intelligent measurement, and its flexible communication module instrument can provide remote management and reading of various communication media. This meter can be used for prepayment (Comply with STS standard)and post payment applications(optional by company).CA168-MJ56 has outstanding anti-tamper feature like terminal cover detection to help users for revenue protection.CA168-MJ56 can utilizes different communication media to ClU or DCU (for Smart Metering application) like PLC/GPRS/3G/4G/RF according to customer requirements.

Products Details

Main Features Dual relay. Multi tariff DLMS/COESM Infrared port/RS485 Tamper detection and record LCD display, read without power Double CT for Phase and Neutral line Disconnects on overload and no credit Prepayment/post-payment mode switching Plug& Play module PLC/GPRS/3G/4G/RF Programmable load limit & Low credit warning Active/reactive energy measurement   Split Configuration for Increased Revenue Protection The CIU (Customer Interface Unit) is optional. The MCU (Metering & Control Unit) and CIU is linked via Mbus 2 wires communication, galvanically-isolated PLC or RF wireless communication, the communication method is on request. The CIU is installed within consumer’s home, while MCU is installed in a meter cabinet away from consumers.  
Electrical parameters:
Voltage
Nominal voltage Un 230V
Limited voltage 70%~120%Un
Frequency  
Nominal frequency fn 50-60Hz
tolerance 5%
Current
Basic current(Ib) 5A
Maximum current(Imax) 60A (100A optional)
Starting current(Ist) 0.4%Ib
Active energy constant 1000imp/kWh
Measurement Accuracy
Active energy to IEC62053-21 Class1.0
Burden  
Voltage circuit <2W  <8VA
Current circuit <1VA
Temperature range
Operation meter -25℃ to+70℃
Storage -40℃ to+85℃
Insulation
Insulation level 4kV rms 1min
Voltage impulse withstand 8kV 1.2/50 μs
Insulation System Classification Protective Class II
Electro Magnetic Compatibility
Electrostatic discharges
Contact discharge 8kV
Air discharge 16kV
Electromagnetic RF fields
27MHz to 500MHz typical 10V/m
100kHz to 1GHz typical 30V/m
Fast transient burst test 4kV
Mechanical requirements
Meter shell Protection Rate IP54
Insulation System Classification Protective Class II
Maximum cable size 8 mm
 

Leave Your Message